Excellence in labglassware

,

2360-ADAPTER, MULTIPLE WITH TWO, NECK ONE VERTICAL & ONE AT 45°& ONE CONE AT BOTTOM

Chemical Resistant

Material: 3.3 boro glass

Chemical Resistant

Material: 3.3 boro glass

PART No. NS FEMALE  size NS MALE  size Pack(Qty)
2360-14F14M 14/23 14/23 10
2360-14F19M 14/23 19/26 10
2360-14F24M 14/23 24/29 10
2360-19F19M 19/26 19/26 10
2360-19F24M 19/26 24/29 10
2360-14F29M 14/23 29/32 10
2360-29F29M 29/32 29/32 10

Here are some potential uses for such an adapter:

  1. Parallel Reactions:
    • The multiple necks allow for the simultaneous setup of parallel reactions in different vessels. The vertical and angled necks enable the connection of various glassware components.
  2. Distillation Setups:
    • The vertical neck can be used for attaching a condenser, while the angled neck allows for the connection of a thermometer or other monitoring devices. The cone at the bottom can be employed for product collection.
  3. Reaction Monitoring:
    • The vertical neck can be used to attach a reflux condenser, allowing for continuous monitoring of reactions. The angled neck can be used for inserting a temperature probe or sampling port.
  4. Vacuum Applications:
    • The adapter can be used in vacuum setups, with the vertical neck serving as an inlet or outlet, and the angled neck accommodating a vacuum gauge or other vacuum-related components.
  5. Fractional Distillation:
    • The combination of a vertical and angled neck is suitable for fractional distillation setups where precise temperature control and vapor monitoring are necessary.
  6. Reflux Setups:
    • The vertical neck is suitable for attaching a reflux condenser, while the angled neck can accommodate a thermometer or other monitoring devices. The cone at the bottom allows for refluxed liquid to be collected.
  7. Synthesis with Multi-step Reactions:
    • In multi-step synthesis, the adapter allows for the setup of different glassware components in a sequential manner, enabling the progression of the reaction through multiple steps.
  8. Reaction with Multiple Components:
    • The multiple necks provide flexibility for reactions involving multiple components, allowing for the addition or removal of reagents at different stages.
  9. Parallel Distillation:
    • When conducting parallel distillation experiments, the adapter can be used to set up multiple distillation units simultaneously.
  10. Chromatography Column Setup:
    • The vertical neck may be used to attach a chromatography column, while the angled neck can accommodate a detector or monitoring device.

Get in Touch

Scroll to Top